HTS1F-CS/CF | LongLine heating cable (Ex) up to +200 ºC
HTS1F is a series resistance, single-conductor heating cable. It is supplied in multiples of three cables for configuring into a 3-phase heating system. It is used for freeze protection or process temperature maintenance of long pipelines up to 5 km, in safe or hazardous areas. A typical application is the temperature maintenance of crude or fuel oils in above-ground or buried transfer lines.
General details
HTS1F-CS/CF is a LONGLINE heating cable of 10 W/m, 20 W/m, 30 W/m, 40 W/m and 50 W/m output, and is used for temperature process maintenance or frost protection of long pipelines. Suitable for use in both, safe and hazardous (Ex) areas, withstand the temperature of up to +200 °C (when switched OFF).
HTS1F-CS/CF cable is designed for heating pipelines of up to 10 km between supply points. The cable is made of silicone rubber and fluoropolymer overjacket, resistant to chemical and environmental hazards.
Installation: The cable is designed for temperature maintenance of long pipelines and frost protection of environmental treatment systems and reservoirs. HTS1F heating cable subtracts several electrical supply points, otherwise needed (these cables are fed from either end of a pipe or the single central power supply located halfway along the pipe). It cuts down the cost of power cables, junction boxes and control devices.